lang

Water supply in the poultry house

We design and install watering systems, which include not only the drinking lines but also the main drinking water supply in the poultry house.

 

Basic elements of main water connection

  1. pressure regulator – watering system protection against excessive pressure,
  2. manometer G1/4 – water pressure measurement,
  3. manometer G1/2 – water pressure measurement,
  4. water meter – measurement of water intake,
  5. water filter – protection of components against deposits,
  6. medicator Dosatron.

Pressure regulator

 

Product characteristics

  • maximum operating temperature: 70OC,
  • maximum inlet pressure of 25 bar,
  • regulated output pressure of 0,5 – 4 bar.

 

Dimensions

 

Size Height Width
3/4" 187mm 95mm

Manometer G1/2

Manometer G1/2 is used for measuring pressure of gases and liquids of low viscosity, not crystallizing and not corrosive. The most important element manometer, responsible for pressure measurement is copper alloy tube, called the Bourdon tube.

 

Manometer characteristics G1/2

  • ambient temperature range -20 …. +60 OC,
  • max temp. medium +60 OC,
  • body material - ABS plastic resistant to impact and corrosion,
  • Bourdon tube made of copper alloy,
  • radial connection,
  • thread ½”,
  • pressure range 0 …10 bar.

Manometer G1/4

Manometer G1/4 is used for measuring pressure of gases and liquids of low viscosity, not crystallizing and not corrosive. The most important element manometer, responsible for pressure measurement is copper alloy tube, called the Bourdon tube.

 

Manometer characteristics G1/4

  • ambient temperature range -20 …. +60 OC,
  • max temp. medium +60 OC,
  • body material - ABS plastic resistant to impact and corrosion,
  • Bourdon tube made of copper alloy,
  • przyłącze rad,
  • thread 1/4”,
  • pressure range 0 …6 bar.

Water meter

Measurement of water intake

  • pipe connection ¾”

Water filter

Protection of components against deposits

  • connection ¾”,
  • 80 microns.

Medicator DOSATRON

Product characteristics

  • is intended to administration of medication and vitamins etc.
  • seals are recommended not only for basic solutions but also acids (such as lactic acid, formic acid),
  • water flow intensity of 10 l / h to 2500 l / h,
  • pressure 0,3-6 bar,
  • solution concentration from 0.2% to 2%,
  • dosage from 0.02 l / h to 50 l / h.
 

Contact data:

Augustowo 6 k/Bydgoszczy
86-022 Dobrcz, POLSKA
More